Find Mobile X-Ray, X-Ray Equipment, X-Ray Unit on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Medical Imaging > Stationary X-Ray Unit > 630mA High Frequency Radiography System

630mA High Frequency Radiography System

Basic Info

Model No.:  XM-HF50-R

Product Description

Model NO.: XM-HF50-R Type: X Ray Equipment Ma Range: 25 ~ 630mA Time Range: 1.0 Ms ~ 5000ms Rated Focal Spot Value: 0.6 Grid Dimension: 356mm × 432mm ( 14"× 17") Trademark: Perlong Origin: Jiangsu, China Classification: Imaging Diagnostic Equipment Certification: ISO13485 Kvp Range: 40 ~ 150kvp Lowest Current Time: 0.5 Mas Table Surface Lock Mode: Electromagnetic Lock Filter Vibrating Mode: Fixed Specification: ISO 630mA High Frequency Radiography System

Generator:
Kvp Range:
Radiography 40 ~ 150KVp
MA Range: Radiography 25 ~ 630mA
Time Range:
Radiography :1.0 ms ~ 5000ms
Lowest Current Time: 0.5 mAs
3-Phase Power Supply: 380VAC± 38VAC
Power Frequency: 50Hz± 1Hz / 60Hz± 1Hz
Power Capacity: 60KVA

X-ray Tube:
Rated Voltage: 150kV
Rated Focal Spot Value: 0.6
Anode Heat Storage Capacity: 2, 30, 000HU
Heat Storage of Tube Assembly: 1, 350, 000HU

Radiographic Table:
Table Surface (L× W× H): 2100× 800× 650 mm
Table Surface Moving Range:
Vertical: 900mm;
Horizontal: 240mm
Table Surface Lock Mode: Electromagnetic lock, braking force≥ 100N
Table Surface Lock Control: Foot switch (permanent on status)
Grid Dimension: 356mm × 432mm ( 14"× 17")
Filter Vibrating Mode: Fixed

Dimension of The Film used in Filter:
Max. 356mm × 432mm (14"× 17") (17" film can only be used in table vertical direction
Source Assembly StandX-Ray Tube components Up-and-Down Motion Range≥ 1220mm
Movement Range Between Tube Focus and Film1100mm
X-Ray Tube Assembly Vertical Motion Range≥ 2380mm
X-Ray Radiation Component Rotating Range Around Support Arm Axis-120° ~ +120°
X-Ray Radiation Component Rotating Range Around the Vertical Axis of the Stand0° ~ ± 90° And 90° Mechanical positioning lock
X-Ray Tube Assembly Locking ForceElectromagnetic locking braking force ≥ 100N

Collimator Mode of Adjustment Manuel
Radiation Field:450× 450mm [Max SID = 100cm]; 2× 2mm [Min SID = 100cm]
Time Limit of the Light Source: ≤ 30s
Ion Chamber:Sensitivity Per Measuring Field60-80 pC/uGy
Difference Of The Measuring Field≤ 5%
Dose Rate Range: 0.5-1000 uGy/s
Exposure Dose Range: 1ms-10s
630mA High Frequency Radiography System

Contact us if you need more details on X-Ray Machine. We are ready to answer your questions on packaging, logistics, certification or any other aspects about X Ray Machine、X Ray Fluroscopy Machine. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Medical Imaging > Stationary X-Ray Unit